WEKO3
アイテム
{"_buckets": {"deposit": "b890a756-842b-4d68-b516-ac71a01f9c51"}, "_deposit": {"created_by": 17, "id": "4083", "owners": [17], "pid": {"revision_id": 0, "type": "depid", "value": "4083"}, "status": "published"}, "_oai": {"id": "oai:yamagata.repo.nii.ac.jp:00004083", "sets": ["107"]}, "author_link": ["12753", "12744", "12749", "12755", "12746", "12752", "12750", "12748", "12754", "12747", "12751", "12745"], "item_3_alternative_title_18": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "新しい麻酔器のPSVにおける吸気トリガー感度について"}]}, "item_3_alternative_title_19": {"attribute_name": "タイトル(ヨミ)", "attribute_value_mlt": [{"subitem_alternative_title": "A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-08-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "108", "bibliographicPageStart": "101", "bibliographicVolumeNumber": "34", "bibliographic_titles": [{"bibliographic_title": "山形大学紀要. 医学 : 山形医学"}, {"bibliographic_title": "Bulletin of the Yamagata University. Medical science : Yamagata medical journal ", "bibliographic_titleLang": "en"}]}]}, "item_3_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_3_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Purpose: The new-generation anesthesia ventilators are better at synchronizing with a patient’s spontaneous respirations, which is important for intensive care. The aim of our study was to evaluate different anesthesia ventilators in pressure-support ventilation mode with regard to aspects of their trigger sensitivity to spontaneous inspiratory breathing.\nMethods: Four anesthesia machines and one intensive-care ventilator were evaluated. The ventilators were connected to a spontaneously breathing test lung. Each anesthesia machine used a different technology for recognizing the change in gas flow, and different flow generators. The trigger sensitivity, the percentage of triggering failures, and the lag time occurring at the time of an intake of air intake were investigated.\nResults: The intensive-care ventilator had the highest trigger sensitivity. The trigger sensitivity of the 4 anesthesia machines was also high. The anesthesia machines from most to least sensitive were as follows: machines equipped with a hot-wire flow meter, an ultrasonic flow meter, or a differential pressure-flow meter. In addition, other structural differences between the machines affected the differences in sensitivity.\nConclusion: The differences between the trigger sensitivity of the tested anesthesia ventilators were a result of differences in the flow-triggering mechanisms and other structures. Although no anesthesiamachines had higher trigger sensitivity than the intensive-care ventilator, the anesthesia machine most recently on the market had very similar trigger sensitivity.", "subitem_description_type": "Other"}]}, "item_3_full_name_2": {"attribute_name": "著者(ヨミ)", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "12748", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "シノハラ, ヨウスケ"}]}, {"nameIdentifiers": [{"nameIdentifier": "12749", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "ヨシオカ, ジュン"}]}, {"nameIdentifiers": [{"nameIdentifier": "12750", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "ナカネ, マサキ"}]}, {"nameIdentifiers": [{"nameIdentifier": "12751", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "カワマエ, カネユキ"}]}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "12752", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shinohara, Yosuke"}]}, {"nameIdentifiers": [{"nameIdentifier": "12753", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yoshioka, Jun"}]}, {"nameIdentifiers": [{"nameIdentifier": "12754", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Nakane, Masaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "12755", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kawamae, Kaneyuki"}]}]}, "item_3_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.15022/00004071", "subitem_identifier_reg_type": "JaLC"}]}, "item_3_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "山形大学"}]}, "item_3_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0288-030X", "subitem_source_identifier_type": "ISSN"}]}, "item_3_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00067279", "subitem_source_identifier_type": "NCID"}]}, "item_3_text_33": {"attribute_name": "出版者(ヨミ)", "attribute_value_mlt": [{"subitem_text_value": "ヤマガタ ダイガク"}]}, "item_3_text_34": {"attribute_name": "別言語の出版者", "attribute_value_mlt": [{"subitem_text_value": "Yamagata University"}]}, "item_3_text_43": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "紀要論文"}]}, "item_3_text_44": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_3_text_45": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_3_text_46": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "篠原, 洋介"}], "nameIdentifiers": [{"nameIdentifier": "12744", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉岡, 淳"}], "nameIdentifiers": [{"nameIdentifier": "12745", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中根, 正樹"}], "nameIdentifiers": [{"nameIdentifier": "12746", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川前, 金幸"}], "nameIdentifiers": [{"nameIdentifier": "12747", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-09-07"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "kiyoum-34-2-101to108.pdf", "filesize": [{"value": "739.3 kB"}], "format": "application/force-download", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/force-download", "size": 739300.0, "url": {"label": "kiyoum-34-2-101to108", "url": "https://yamagata.repo.nii.ac.jp/record/4083/files/kiyoum-34-2-101to108.pdf"}, "version_id": "19c0f498-ba3d-40a3-ab2b-4dfbefd1ca9b"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode"}]}, "item_type_id": "3", "owner": "17", "path": ["107"], "permalink_uri": "https://doi.org/10.15022/00004071", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-09-01"}, "publish_date": "2016-09-01", "publish_status": "0", "recid": "4083", "relation": {}, "relation_version_is_last": true, "title": ["A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode"], "weko_shared_id": -1}
A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode
https://doi.org/10.15022/00004071
https://doi.org/10.15022/00004071ac130766-5b8e-49ca-9091-1eaae1104be8
名前 / ファイル | ライセンス | アクション |
---|---|---|
kiyoum-34-2-101to108 (739.3 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-09-01 | |||||
タイトル | ||||||
タイトル | A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.15022/00004071 | |||||
ID登録タイプ | JaLC | |||||
著者 |
篠原, 洋介
× 篠原, 洋介× 吉岡, 淳× 中根, 正樹× 川前, 金幸 |
|||||
著者(ヨミ) | ||||||
姓名 | シノハラ, ヨウスケ | |||||
著者(ヨミ) | ||||||
姓名 | ヨシオカ, ジュン | |||||
著者(ヨミ) | ||||||
姓名 | ナカネ, マサキ | |||||
著者(ヨミ) | ||||||
姓名 | カワマエ, カネユキ | |||||
著者別名 | ||||||
姓名 | Shinohara, Yosuke | |||||
著者別名 | ||||||
姓名 | Yoshioka, Jun | |||||
著者別名 | ||||||
姓名 | Nakane, Masaki | |||||
著者別名 | ||||||
姓名 | Kawamae, Kaneyuki | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Purpose: The new-generation anesthesia ventilators are better at synchronizing with a patient’s spontaneous respirations, which is important for intensive care. The aim of our study was to evaluate different anesthesia ventilators in pressure-support ventilation mode with regard to aspects of their trigger sensitivity to spontaneous inspiratory breathing. Methods: Four anesthesia machines and one intensive-care ventilator were evaluated. The ventilators were connected to a spontaneously breathing test lung. Each anesthesia machine used a different technology for recognizing the change in gas flow, and different flow generators. The trigger sensitivity, the percentage of triggering failures, and the lag time occurring at the time of an intake of air intake were investigated. Results: The intensive-care ventilator had the highest trigger sensitivity. The trigger sensitivity of the 4 anesthesia machines was also high. The anesthesia machines from most to least sensitive were as follows: machines equipped with a hot-wire flow meter, an ultrasonic flow meter, or a differential pressure-flow meter. In addition, other structural differences between the machines affected the differences in sensitivity. Conclusion: The differences between the trigger sensitivity of the tested anesthesia ventilators were a result of differences in the flow-triggering mechanisms and other structures. Although no anesthesiamachines had higher trigger sensitivity than the intensive-care ventilator, the anesthesia machine most recently on the market had very similar trigger sensitivity. |
|||||
書誌情報 |
山形大学紀要. 医学 : 山形医学 en : Bulletin of the Yamagata University. Medical science : Yamagata medical journal 巻 34, 号 2, p. 101-108, 発行日 2016-08-15 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0288-030X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00067279 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | 新しい麻酔器のPSVにおける吸気トリガー感度について | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | A Bench Study of New-Generation Anesthesia Ventilators: Inspiratory Trigger Sensitivity in Pressure-Support Mode | |||||
出版者 | ||||||
出版者 | 山形大学 | |||||
出版者(ヨミ) | ||||||
ヤマガタ ダイガク | ||||||
別言語の出版者 | ||||||
Yamagata University | ||||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
紀要論文 | ||||||
資源タイプ・NII | ||||||
Departmental Bulletin Paper | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
2 |