{"created":"2023-05-25T05:26:08.443797+00:00","id":4823,"links":{},"metadata":{"_buckets":{"deposit":"a7ca0b16-d8d6-48b7-a76f-3763e4173ebb"},"_deposit":{"created_by":17,"id":"4823","owners":[17],"pid":{"revision_id":0,"type":"depid","value":"4823"},"status":"published"},"_oai":{"id":"oai:yamagata.repo.nii.ac.jp:00004823","sets":["29:31:176:177"]},"author_link":["14651","14657","14660","14658","14653","14652","14655","14656","14659","14654"],"item_3_alternative_title_18":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"頭低位、気腹を伴うロボット支援手術における、脈波伝播時間を用いた非侵襲的心拍出量計の使用経験"}]},"item_3_alternative_title_19":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"トウテイイ キフク ヲ トモナウ ロボット シエン シュジュツ ニ オケル ミャクハ デンパン ジカン ヲ モチイタ ヒシンシュウテキ シンハクシュツリョウケイ ノ シヨウ ケイケン"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-02-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"42","bibliographicPageStart":"38","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"山形大学紀要. 医学 : 山形医学 "},{"bibliographic_title":"Bulletin of the Yamagata University. Medical science : Yamagata medical journal","bibliographic_titleLang":"en"}]}]},"item_3_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article) ","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Background: Estimated continuous cardiac output(esCCO)is a non-invasive technique for monitoring continuous cardiac output(CCO)that is based on pulse-wave transit time. In this study, we report the use of CCO monitoring for patients undergoing robot-assisted surgery with pneumoperitoneum in a head-down position. \nMethod: Thirteen patients undergoing radical robot-assisted prostatectomy under general anesthesia were enrolled. Intraoperatively, esCCO and arterial pressure-based cardiac output(APCO)were simultaneously recorded. The association between esCCO and APCO was then evaluated using correlation analysis and Bland-Altman analysis. The trending ability of esCCO was evaluated by 4-quadrant plot analysis. \nResults: The correlation coefficient between esCCO and APCO was 0.54(P < 0.0001). According to the Bland-Altman plot, the bias and precision values were 1.38 and 0.79 L/min, respectively. The concordance analysis showed the concordance rate of 92.3%. \nConclusion: These results indicate that esCCO is capable of tracking hemodynamic changes associated with pneumoperitoneum in the head-down position.","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"14656","nameIdentifierScheme":"WEKO"}],"names":[{"name":"黒田, 美聡"}]},{"nameIdentifiers":[{"nameIdentifier":"14657","nameIdentifierScheme":"WEKO"}],"names":[{"name":"高橋, 達朗"}]},{"nameIdentifiers":[{"nameIdentifier":"14658","nameIdentifierScheme":"WEKO"}],"names":[{"name":"秋元 , 亮"}]},{"nameIdentifiers":[{"nameIdentifier":"14659","nameIdentifierScheme":"WEKO"}],"names":[{"name":"中根, 正樹"}]},{"nameIdentifiers":[{"nameIdentifier":"14660","nameIdentifierScheme":"WEKO"}],"names":[{"name":"川前, 金幸"}]}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15022/00004779","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"山形大学"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0288-030X ","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00067279 ","subitem_source_identifier_type":"NCID"}]},"item_3_text_33":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ヤマガタ ダイガク"}]},"item_3_text_34":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"Yamagata University "}]},"item_3_text_43":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文 "}]},"item_3_text_44":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper "}]},"item_3_text_45":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text "}]},"item_3_text_46":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kurota, Misato "}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takahashi, Tatsuro "}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Akimoto, Ryo "}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakane, Masaki "}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kawamae, Kaneyuki "}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-12"}],"displaytype":"detail","filename":"kiyoum-38-1-38to42.pdf","filesize":[{"value":"771.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyoum-38-1-38to42","url":"https://yamagata.repo.nii.ac.jp/record/4823/files/kiyoum-38-1-38to42.pdf"},"version_id":"dbaad974-912d-4019-9066-880a79a9e1eb"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"continuous cardiac output, head-down position, pnuemoperitoneum","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Experience of using a non-invasive pulse-wave transit time-based cardiac output monitoring in patients undergoing robot-assisted surgery with pneumoperitoneum in a head-down position","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Experience of using a non-invasive pulse-wave transit time-based cardiac output monitoring in patients undergoing robot-assisted surgery with pneumoperitoneum in a head-down position"}]},"item_type_id":"3","owner":"17","path":["177"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-02-18"},"publish_date":"2020-02-18","publish_status":"0","recid":"4823","relation_version_is_last":true,"title":["Experience of using a non-invasive pulse-wave transit time-based cardiac output monitoring in patients undergoing robot-assisted surgery with pneumoperitoneum in a head-down position"],"weko_creator_id":"17","weko_shared_id":-1},"updated":"2023-05-25T06:19:31.413186+00:00"}