{"created":"2023-05-25T05:23:09.821254+00:00","id":575,"links":{},"metadata":{"_buckets":{"deposit":"2bc169ff-7baa-473a-b640-6af7c7b238a9"},"_deposit":{"created_by":3,"id":"575","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"575"},"status":"published"},"_oai":{"id":"oai:yamagata.repo.nii.ac.jp:00000575","sets":["34:36"]},"author_link":["2456","2455"],"item_3_alternative_title_18":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Studies on Spectroscopic Imaging Measurements of Optical Transmission Characteristics of Biological Tissues Using an Optical Heterodyne Detection Method"}]},"item_3_alternative_title_19":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ヒカリ ヘテロダイン ケンシュツホウ オ モチイタ セイタイ シリョウ ノ ヒカリ トウカ トクセイ ニ カンスル ブンコウ ガゾウ ケイソクホウ ノ ケンキュウ"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-02-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"81","bibliographicPageStart":"71","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"山形大学紀要.工学"}]}]},"item_3_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"We constructed a new spectroscopic imaging system that is a highly sensitive space-resolving spectrophotometer based on an optical heterodyne detection method using a tunable laser. First, we constructed a Mach-Zehnder interferometer using an acousto-optic modulator in order to generate the beat component. This interferometer incorporates two concave mirrors that correct the optical axis slip even if the laser wavelength varies, Next, we constructed an improved high-dynamic-range spectroscopic image system without concave mirrors using an optical heterodyne detection method, Using this system, we measured the spectroscopic characteristics of neodymium glass in a diluted solution of Intralipid -20% as a highly scattering medium. We also acquired a two-dimensional image of a test target in a highly scattering medium at different wavelengths. As a result, we were able to acquire two-dimensional absorbed images of some bio1ogical tissues at different laser wavelengths.","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"2456","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ichimura, Tsutomu"}]}]},"item_3_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"山形大学"}]},"item_3_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00242991","subitem_source_identifier_type":"NCID"}]},"item_3_text_33":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ヤマガタ ダイガク"}]},"item_3_text_34":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"Yamagata University"}]},"item_3_text_43":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_44":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_45":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_46":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"市村, 勉"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-08-21"}],"displaytype":"detail","filename":"kiyoue-29-2-071to081.pdf","filesize":[{"value":"913.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyoue-29-2-071to081.pdf","url":"https://yamagata.repo.nii.ac.jp/record/575/files/kiyoue-29-2-071to081.pdf"},"version_id":"055e09ec-6d6e-4e2a-a5db-d0000ff2b7da"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"光ヘテロダイン検出法を用いた生体試料の光透過特性に関する分光画像計測法の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"光ヘテロダイン検出法を用いた生体試料の光透過特性に関する分光画像計測法の研究"}]},"item_type_id":"3","owner":"3","path":["36"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-09-06"},"publish_date":"2007-09-06","publish_status":"0","recid":"575","relation_version_is_last":true,"title":["光ヘテロダイン検出法を用いた生体試料の光透過特性に関する分光画像計測法の研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-25T07:15:41.231832+00:00"}