{"created":"2023-05-25T05:23:23.319971+00:00","id":851,"links":{},"metadata":{"_buckets":{"deposit":"8bbd6428-a609-4af1-9dfd-b7c05551e115"},"_deposit":{"created_by":3,"id":"851","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"851"},"status":"published"},"_oai":{"id":"oai:yamagata.repo.nii.ac.jp:00000851","sets":["34:36"]},"author_link":["3641","3640"],"item_3_alternative_title_18":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Effects of AC Supply Voltage Variation on Reset Flux Change of Full-Wave Type Magnetic Amplifier and the Method of its Compensation"}]},"item_3_alternative_title_19":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ゼンハケイ ジキ ゾウフクキ ノ リセット ジソクリョウ ニ オヨボス デンゲン ヘンドウ ノ エイキョウ ト ソノ ホショウホウ"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1969-03-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"458","bibliographicPageStart":"447","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"山形大学紀要.工学"}]}]},"item_3_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"The fluctuation of the reset flux change is caused by AC supply voltage variation when the resistance of the control circuit of the full-wave type magnetic amplifier is small. This paper shows how AC supply voltage variation has an effect on the reset flux change, and presents two methods of its compensation. One of them is a series compensation, the other is a parallel one. The former is comopsed of transistors, diodes and AC supply source and the voltage applied to the resistance of the control circuit counteracts induced voltage on the control windings. The latter is a simple circuit that is composed of one resistance and two compensating windings with inverse polality each other. It can be said from the experimental results that these methods have an excellent compensating effect. Thercfore they can be adopted to the firing circuit of SCR amplifier with compensating circuit for AC supply voltage variation. It is also experimentally verified that these methods not only compensate for the supply voltage variation but also have a fast transient response in case of the perfect compensation.","subitem_description_type":"Other"}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"3641","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Oyama, Shigeru"}]}]},"item_3_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"山形大学"}]},"item_3_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00242991","subitem_source_identifier_type":"NCID"}]},"item_3_text_33":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ヤマガタ ダイガク"}]},"item_3_text_34":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"Yamagata University"}]},"item_3_text_43":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_44":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_45":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_46":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"尾山, 茂"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-08-21"}],"displaytype":"detail","filename":"kiyoue-10-2-24-1_merged.pdf","filesize":[{"value":"547.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"kiyoue-10-2-24-1_merged.pdf","url":"https://yamagata.repo.nii.ac.jp/record/851/files/kiyoue-10-2-24-1_merged.pdf"},"version_id":"75557fcf-8e73-42dd-802c-808d118eefb2"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"全波形磁気増幅器のリセット磁束量におよぼす電源変動の影響とその補償法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"全波形磁気増幅器のリセット磁束量におよぼす電源変動の影響とその補償法"}]},"item_type_id":"3","owner":"3","path":["36"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-09-06"},"publish_date":"2007-09-06","publish_status":"0","recid":"851","relation_version_is_last":true,"title":["全波形磁気増幅器のリセット磁束量におよぼす電源変動の影響とその補償法"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-25T07:10:53.443526+00:00"}