WEKO3
アイテム
{"_buckets": {"deposit": "36329f00-8210-4f36-bbb7-d2c7969abd21"}, "_deposit": {"created_by": 3, "id": "221", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "221"}, "status": "published"}, "_oai": {"id": "oai:yamagata.repo.nii.ac.jp:00000221", "sets": ["116"]}, "author_link": ["977", "975", "976", "979", "978", "982", "984", "981", "980", "983"], "item_3_alternative_title_18": {"attribute_name": "その他の言語のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Clinical study on the usefulness of total knee arthroplasty using navigation system"}]}, "item_3_alternative_title_19": {"attribute_name": "タイトル(ヨミ)", "attribute_value_mlt": [{"subitem_alternative_title": "ジンコウ ヒザカンセツ ゼンチカンジュツ ニオケル ナビゲーション システム ノ ユウヨウセイ ニ カンスル リンショウテキ ケントウ"}]}, "item_3_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-08-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "46", "bibliographicPageStart": "37", "bibliographicVolumeNumber": "31", "bibliographic_titles": [{"bibliographic_title": "山形大学紀要. 医学 : 山形医学 = Bulletin of the Yamagata University. Medical science : Yamagata medical journal"}]}]}, "item_3_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "論文(Article)", "subitem_description_type": "Other"}]}, "item_3_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "【背景】コンピュータ支援手術であるナビゲーションシステム(ナビ)は精緻で正確な手術を可能とし、人工膝関節全置換術(TKA)にも応用されるようになってきた。本研究では山形大学で行ったナビを用いたTKA(ナビTKA)の有用性について検討することを目的とした。対象と方法】2007年3月より2012年7月まで山形大学医学部附属病院にてTKAを行った症例119例143膝を対象とした。ナビを使用した群(ナビ群)は74例(70.5±11.1歳)86膝(男性14膝、女性72膝)、原因疾患は変形性膝関節症(OA)61膝、関節リウマチ(RA)25膝であった。ナビ群と比較する目的で2011年4月から2012年7月までの期間に従来の手術方法でTKAを行った群(従来群)は45例(71.9±9.7歳)57膝(男性14膝、女性43膝)、原因疾患はOA40膝、RA17膝であった。ナビTKAにおいて、大腿骨、脛骨の骨表面、関節表面のレジストレーション誤差、手術手技(ガイド設置、骨切り)の誤差を評価し、人工関節の設置角度、手術時間、問題点について従来群と比較検討した。【結果と考察】関節、骨表面の平均レジストレーション誤差は、大腿骨では内顆関節面0.76mm、外顆関節面0.64mm、内側上顆0.41mm、外側上顆0.36mm、前方骨皮質0.20mmであった。脛骨では内顆関節面1.13mm、外顆関節面0.87mm、脛骨粗面0.09mm、内顆骨皮質では0.22mmであった。骨切りガイドの誤差は、初回の骨切りの誤差よりも大きかったが、修正の骨切りを行うことにより、補正することができた。単純X線によるコンポーネント設置角度は大腿骨で89.9°、脛骨で90.5°であり、3°以上の誤差を認めた症例はナビ群で大腿骨と脛骨ともに5.1%と従来の手術と比べて逸脱率が有意に小さかった。手術時間は従来法と比較して平均24分の延長を認めた。ナビ手術に関連する重篤な有害事象は認められなかった。【結論】ナビはTKAにおける正確な手術の実施のために有用と考えられた。", "subitem_description_type": "Other"}]}, "item_3_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "980", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Asano, Tamon"}]}, {"nameIdentifiers": [{"nameIdentifier": "981", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Narita, Atsushi"}]}, {"nameIdentifiers": [{"nameIdentifier": "982", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Oki, Hiroharu"}]}, {"nameIdentifiers": [{"nameIdentifier": "983", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Takakubo, Yuya"}]}, {"nameIdentifiers": [{"nameIdentifier": "984", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Takagi, Michiaki"}]}]}, "item_3_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "山形大学"}]}, "item_3_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00067279", "subitem_source_identifier_type": "NCID"}]}, "item_3_text_33": {"attribute_name": "出版者(ヨミ)", "attribute_value_mlt": [{"subitem_text_value": "ヤマガタ ダイガク"}]}, "item_3_text_34": {"attribute_name": "別言語の出版者", "attribute_value_mlt": [{"subitem_text_value": "Yamagata University"}]}, "item_3_text_43": {"attribute_name": "資源タイプ・ローカル", "attribute_value_mlt": [{"subitem_text_value": "紀要論文"}]}, "item_3_text_44": {"attribute_name": "資源タイプ・NII", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper"}]}, "item_3_text_45": {"attribute_name": "資源タイプ・DCMI", "attribute_value_mlt": [{"subitem_text_value": "text"}]}, "item_3_text_46": {"attribute_name": "資源タイプ・ローカル表示コード", "attribute_value_mlt": [{"subitem_text_value": "2"}]}, "item_3_text_67": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://repo.lib.yamagata-u.ac.jp/handle/123456789/11744"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "浅野, 多聞"}], "nameIdentifiers": [{"nameIdentifier": "975", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "成田, 淳"}], "nameIdentifiers": [{"nameIdentifier": "976", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大木, 弘治"}], "nameIdentifiers": [{"nameIdentifier": "977", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高窪, 祐弥"}], "nameIdentifiers": [{"nameIdentifier": "978", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高木, 理彰"}], "nameIdentifiers": [{"nameIdentifier": "979", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-08-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "kiyoum-31-2-037to046.pdf", "filesize": [{"value": "633.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 633800.0, "url": {"label": "kiyoum-31-2-037to046.pdf", "url": "https://yamagata.repo.nii.ac.jp/record/221/files/kiyoum-31-2-037to046.pdf"}, "version_id": "f8270cad-dee1-43a8-8ac9-22919fc78053"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "人工膝関節全置換術におけるナビゲーションシステムの 有用性に関する臨床的検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "人工膝関節全置換術におけるナビゲーションシステムの 有用性に関する臨床的検討"}]}, "item_type_id": "3", "owner": "3", "path": ["116"], "permalink_uri": "https://yamagata.repo.nii.ac.jp/records/221", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-09-03"}, "publish_date": "2013-09-03", "publish_status": "0", "recid": "221", "relation": {}, "relation_version_is_last": true, "title": ["人工膝関節全置換術におけるナビゲーションシステムの 有用性に関する臨床的検討"], "weko_shared_id": 3}
人工膝関節全置換術におけるナビゲーションシステムの 有用性に関する臨床的検討
https://yamagata.repo.nii.ac.jp/records/221
https://yamagata.repo.nii.ac.jp/records/2212abb7d13-647a-440a-9d3a-2360a45fab93
名前 / ファイル | ライセンス | アクション |
---|---|---|
kiyoum-31-2-037to046.pdf (633.8 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-09-03 | |||||
タイトル | ||||||
タイトル | 人工膝関節全置換術におけるナビゲーションシステムの 有用性に関する臨床的検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
浅野, 多聞
× 浅野, 多聞× 成田, 淳× 大木, 弘治× 高窪, 祐弥× 高木, 理彰 |
|||||
著者別名 | ||||||
姓名 | Asano, Tamon | |||||
著者別名 | ||||||
姓名 | Narita, Atsushi | |||||
著者別名 | ||||||
姓名 | Oki, Hiroharu | |||||
著者別名 | ||||||
姓名 | Takakubo, Yuya | |||||
著者別名 | ||||||
姓名 | Takagi, Michiaki | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 【背景】コンピュータ支援手術であるナビゲーションシステム(ナビ)は精緻で正確な手術を可能とし、人工膝関節全置換術(TKA)にも応用されるようになってきた。本研究では山形大学で行ったナビを用いたTKA(ナビTKA)の有用性について検討することを目的とした。対象と方法】2007年3月より2012年7月まで山形大学医学部附属病院にてTKAを行った症例119例143膝を対象とした。ナビを使用した群(ナビ群)は74例(70.5±11.1歳)86膝(男性14膝、女性72膝)、原因疾患は変形性膝関節症(OA)61膝、関節リウマチ(RA)25膝であった。ナビ群と比較する目的で2011年4月から2012年7月までの期間に従来の手術方法でTKAを行った群(従来群)は45例(71.9±9.7歳)57膝(男性14膝、女性43膝)、原因疾患はOA40膝、RA17膝であった。ナビTKAにおいて、大腿骨、脛骨の骨表面、関節表面のレジストレーション誤差、手術手技(ガイド設置、骨切り)の誤差を評価し、人工関節の設置角度、手術時間、問題点について従来群と比較検討した。【結果と考察】関節、骨表面の平均レジストレーション誤差は、大腿骨では内顆関節面0.76mm、外顆関節面0.64mm、内側上顆0.41mm、外側上顆0.36mm、前方骨皮質0.20mmであった。脛骨では内顆関節面1.13mm、外顆関節面0.87mm、脛骨粗面0.09mm、内顆骨皮質では0.22mmであった。骨切りガイドの誤差は、初回の骨切りの誤差よりも大きかったが、修正の骨切りを行うことにより、補正することができた。単純X線によるコンポーネント設置角度は大腿骨で89.9°、脛骨で90.5°であり、3°以上の誤差を認めた症例はナビ群で大腿骨と脛骨ともに5.1%と従来の手術と比べて逸脱率が有意に小さかった。手術時間は従来法と比較して平均24分の延長を認めた。ナビ手術に関連する重篤な有害事象は認められなかった。【結論】ナビはTKAにおける正確な手術の実施のために有用と考えられた。 | |||||
書誌情報 |
山形大学紀要. 医学 : 山形医学 = Bulletin of the Yamagata University. Medical science : Yamagata medical journal 巻 31, 号 2, p. 37-46, 発行日 2013-08-15 |
|||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00067279 | |||||
その他の言語のタイトル | ||||||
その他のタイトル | Clinical study on the usefulness of total knee arthroplasty using navigation system | |||||
タイトル(ヨミ) | ||||||
その他のタイトル | ジンコウ ヒザカンセツ ゼンチカンジュツ ニオケル ナビゲーション システム ノ ユウヨウセイ ニ カンスル リンショウテキ ケントウ | |||||
出版者 | ||||||
出版者 | 山形大学 | |||||
出版者(ヨミ) | ||||||
ヤマガタ ダイガク | ||||||
別言語の出版者 | ||||||
Yamagata University | ||||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | 論文(Article) | |||||
資源タイプ・ローカル | ||||||
紀要論文 | ||||||
資源タイプ・NII | ||||||
Departmental Bulletin Paper | ||||||
資源タイプ・DCMI | ||||||
text | ||||||
資源タイプ・ローカル表示コード | ||||||
2 |